The N-Probe is a low power potentiostat designed to connect with a Zennium workstation, and not as a standalone device. It comes specially equipped with hardware for all common electrochemical noise techniques. In addition, Zahner developed CorrElNoise® which is a revolutionary new method superior to common ECN techniques.

 

Noise based corrosion research using conventional electrochemical methods focus on the fact that the initial redox processes are related to the charge transfer of the metal dissolution deposition processes. Distinct areas of the object surface can be viewed as local galvanic elements that contribute to the total measured potential. Since many of these local elements are superimposed, the fluctuation of the potential (and the current, if the electrode is polarized) is low. Traditional electrochemical methods are based on this "steady state" behavior. However, inhomogeneous corrosion attack, which is particularly important in the nucleation phase, does not conform to these conditions. Traditional methods such as impedance or Tafel techniques will fail for such inhomogeneous corroding objects, because the measurement signals become more and more noisy. In this case noise measurements quantify these discrete events that are disturbing the continuous methods.

 

For analysis, it is of great value to measure both current and potential noise. The problem is that measurement of current noise essentially requires a short circuit condition, whereas potential noise must be measured with a high impedance load. The standard method for solving this problem is to measure two identical systems, one under open circuit, the other under short circuit condition. A common experimental arrangement uses three identical electrodes, where one pair acts as a current noise source under short-circuit conditions, the second as a potential noise source under open circuit condition. One electrode acts as a common electrode.

 

This arrangement is often used in monitoring applications, and can be set up with a Zennium equipped with a EPC42 and N-Probe. However, this method has a significant disadvantage in that the measured current and potential noise do not come from the same electrochemical system. Even though it is assumed that the corrosion behavior of both systems is identical, the current and the potential are not correlated. This means that only the scalar values can be related, and vector operations like power calculation are meaningless.

 

There is a solution for the problem, based on the fact that corrosion-related noise is observed mainly in the low frequency range. To a first approximation, the noise source may be described as a low frequency noise oscillator in series with a source resistance. Therefore it is possible to sample both current and potential signals by rapidly switching between the two modes (open circuit and short circuit). If the switching/sampling frequency is high relative to the highest noise frequency of interest, this technique works without loss of information.

 

CorrElNoise, developed by the specialists at Zahner, is based on these principles. CorrElNoise stands for the measurement of CORRelated ELectrochemical current and potential NOISE coming from the same source. The method is available both as a plug-in for the Zennium and as a stand-alone system. It enables the user to record current, potential and power noise in the frequency range from DC up to about 5 Hz. Furthermore, CorrElNoise benefits from the chopper principle. This means that electronic offset and drift problems, as well as line frequency interference, are automatically suppressed.

 

As noise measurements normally have a long acquisition time, there is a lot of data to be handled. The NOISE software allows to save measurement data in two ways: Normally the software reduces the flood of data by a factor of 260. Then you have access to the most often used analysis mode, the frequency spectrum of the noise signal. In addition the time-domain signal can be saved so that any other analysis method can be applied after the acquisition. Time-domain data are compressed with a factor of 8.

Electrochemical Noise Probe

  • Operating modes

    Pot/Gal/OC

    Potential range

    ±2.5 V / ±10 V

    Potential accuracy

    ±0.1% / ±2.5 mV

    Current range

    0 A … ±20 mA

    Current accuracy

    ±0.1 % / ±20 µA

    Frequency range

    10µHz - 200kHz

    Input impedance

    10 TΩ || 12 pF

    Ambient temperature

    0C … 30C

    Dimensions

    190 x 100 x 40 mm

    Weight

    500 g

    System requirements

    ZENNIUM-series workstation+EPC42

CALL US: +1 480 256 8706

Available Mon-Fri 9am-5pm UTC-07:00

Appointments schedulable at any time

EMAIL US QUESTIONS

Email support@admiralinstruments.com

Responses sent within one business day

LOCATED OUTSIDE THE USA?

We have international distribution available Email sales@admiralinstruments.com for info

ENGAGE WITH US ON SOCIAL MEDIA
  • LinkedIn Social Icon
  • Twitter Social Icon
  • YouTube Social  Icon
ELECTROCHEMISTRY &
PHOTO-ELECTROCHEMISTRY

- Potentiostats / Galvanostats

- Electrochemical Impedance Spectroscopy

- High-current Loads for Batteries & Fuel Cells

- Solar Cell Analysis & Optimization

- Corrosion Monitoring & Modeling

VISIT OUR OFFICE LOCATED IN TEMPE, ARIZONA

Admiral Instruments

2245 W University Dr

Suite 7

Tempe, Arizona 85281

USA

© 2019 by Admiral Instruments LLC. All Rights Reserved.